Dentomaxillofacial Radiology, Vol 20, Issue 3 135-146, Copyright © 1991 by British Institute of Radiology


ARTICLES

Influence of scattered radiation and tube potential on radiographic contrast: comparison of two different dental X-ray films

E. Helmrot, G. A. Carlsson, O. Eckerdal and M. Sandborg
Department of Radiation Physics, Faculty of Health Sciences, The Medical School, Linkoping, Sweden.

The fundamental concept in image quality of contrast has been analysed in terms of its elements; film, radiation and object contrast, and the theoretical formula to describe their interrelationship have been evaluated. Experiments were designed to investigate the dependence of radiographic contrast on the kV, the type of generator and dental film used (D and E speed). An ivory wedge was used as the object, both alone and within a polymethyl methacrylate phantom as scattering medium. Precise definition and control of the X-ray generators were achieved by means of measurements of the primary X-ray spectra using a Compton spectrometer. D speed was found to have higher film contrast than E speed when compared at the same optical density, due to its lower base and fog and lower level of saturation in these experiments. On the other hand, E speed was found to have wider latitude. The experimental object was reproduced with the highest radiographic contrast using D-speed film and, with a given type of generator, this increased when the kV was decreased. While no difference in scatter/primary ratios was observed using the two different films, a weak dependence on kV in the range from 36 to 77 kV was found and confirmed by Monte Carlo calculations. The results indicate that the D and E speed films used had equal energy absorption properties; the difference in radiographic performance is due to their different film characteristics. The importance of controlling the physical parameters (photon energy spectrum, base and fog and optical density level) when comparing image qualities is clearly demonstrated.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
Diagnostic accuracy of in vitro panoramic radiographs depending on the exposure
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 68 - 74.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1991 by the British Institute of Radiology.