DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ekestubbe, A.
Right arrow Articles by Grondahl, H. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ekestubbe, A.
Right arrow Articles by Grondahl, H. G.

Dentomaxillofacial Radiology, Vol 21, Issue 2 65-69, Copyright © 1992 by British Institute of Radiology


ARTICLES

Absorbed doses and energy imparted from tomography for dental implant installation. Spiral tomography using the Scanora technique compared with hypocycloidal tomography

A. Ekestubbe, A. Thilander and H. G. Grondahl
University of Goteborg, Sweden.

Tomography is sometimes needed to obtain information on the amount of bone available in the maxilla and in the posterior parts of the mandible prior to implant surgery. Both conventional and computed tomography can be employed. Recently a new imaging device, the Scanora, has been introduced which can be used for spiral tomography. The aim of this study was to compare absorbed doses and energy imparted from this new unit with those from conventional hypocycloidal tomography using the Philips Universal Polytome. A multi-film cassette with five pairs of calcium tungstate screens was used in the latter while a single film technique was used with the Scanora. The absorbed dose measurements were made on an anthropomorphic phantom. Most absorbed doses were found to be below 0.2 mGy except those to the major salivary glands. The absorbed doses with the Scanora were higher than with the Polytome. The beam direction and shorter focus-object distance in the Scanora influenced the absorbed dose distribution. The energy imparted was found to be low for both techniques, 1.8-1.9 mJ with the Scanora for both jaws, and for hypocycloidal tomography 0.78 mJ in the maxilla and 1.3 mJ in the mandible.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
M. Lagravere, Y Fang, J Carey, R. Toogood, G. Packota, and P. Major
Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000
Dentomaxillofac. Radiol., November 1, 2006; 35(6): 407 - 409.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, H-G Grondahl, and B Molander
Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose
Dentomaxillofac. Radiol., September 1, 2003; 32(5): 322 - 326.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1992 by the British Institute of Radiology.