DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, S. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, S. C.

Dentomaxillofacial Radiology, Vol 21, Issue 3 118-126, Copyright © 1992 by British Institute of Radiology


ARTICLES

1992 assessment of radiation risk from dental radiography

S. C. White
School of Dentistry, Los Angeles, California.

Recent studies suggest that the lifetime cancer risks from exposure to low levels of ionizing radiation may be greater than previously estimated. This review first summarizes the findings of these studies as they pertain to dental radiology, then uses their concepts in combination with dosimetry from the dental literature to estimate the radiation risk from dental radiology. Estimation of risk from groups of exposed individuals requires use of mathematical models that fit the epidemiological data. The ICRP estimates that a single brief whole-body exposure of 1 Gy to 10,000 people results in about 500 additional cancer deaths over the lifetime of the exposed individuals, assuming a dose rate effectiveness factor of 2 for cancers other than leukaemia. Leukaemias are seen as a wave from 5 to 30 years following exposure. Cancers other than leukaemia typically start to appear about 10 years following exposure and remain in excess for as long as most exposed populations are followed, presumably for the lifetime of the exposed individuals. The gonadal dose is so small from dental radiography that the risk of heritable defects is negligible in comparison with the somatic risk. The dental literature contains several studies reporting sufficient dosimetric data for radiosensitive sites in the head and neck to allow estimation of the risk of fatal cancers from intra-oral and panoramic radiography. The highest estimated risks (using the ICRP data) are for leukaemia (bone marrow), thyroid and bone surface cancer. The total risk is estimated to be 2.5 fatal malignancies per 10(6) full-mouth examinations made with D-speed film and round collimation.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Kaeppler, M. Buchgeister, and S. Reinert
Influence of the rotation centre in panoramic radiography
Radiat Prot Dosimetry, January 1, 2008; 128(2): 239 - 244.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, K Herz, and S Reinert
Factors influencing the absorbed dose in intraoral radiography
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 506 - 513.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. Poppe, H. K. Looe, A. Pfaffenberger, N. Chofor, F. Eenboom, M. Sering, A. Ruhmann, A. Poplawski, and K. Willborn
Dose-area product measurements in panoramic dental radiology
Radiat Prot Dosimetry, January 1, 2007; 123(1): 131 - 134.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
N Akkaya, O Kansu, H Kansu, L. Cagirankaya, and U Arslan
Comparing the accuracy of panoramic and intraoral radiography in the diagnosis of proximal caries.
Dentomaxillofac. Radiol., May 1, 2006; 35(3): 170 - 174.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Helmrot and G. Alm Carlsson
Measurement of radiation dose in dental radiology
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 168 - 171.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F Gijbels, R Jacobs, R Bogaerts, D Debaveye, S Verlinden, and G Sanderink
Dosimetry of digital panoramic imaging. Part I: patient exposure
Dentomaxillofac. Radiol., May 1, 2005; 34(3): 145 - 149.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
C. E. Tierris, E. N. Yakoumakis, G. N. Bramis, and E. Georgiou
Dose area product reference levels in dental panoramic radiology
Radiat Prot Dosimetry, October 11, 2004; 111(3): 283 - 287.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, A Thilander-Klang, A Lith, and H-G Grondahl
Effective and organ doses from scanography and zonography: a comparison with periapical radiography
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 87 - 92.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
J. Ludlow, L. Davies-Ludlow, and S. Brooks
Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit
Dentomaxillofac. Radiol., July 1, 2003; 32(4): 229 - 234.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1992 by the British Institute of Radiology.