DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Vannier, M. W.

Dentomaxillofacial Radiology, Vol 23, Issue 3 129-134, Copyright © 1994 by British Institute of Radiology


ARTICLES

Bitewing-based alveolar bone densitometry: digital imaging resolution requirements

C. F. Hildebolt, T. Q. Bartlett, B. S. Brunsden, N. L. Hente, M. J. Gravier, R. K. Walkup, M. K. Shrout and M. W. Vannier
Mallinckrodt Institute of Radiology, Washington University Medical School, St. Louis.

The resolution requirements were determined for detection of incremental alveolar bone loss from digitized Ektaspeed radiographs. Ten clinical radiographs were examined with a calibrated optical microscope to measure the smallest feature of interest discernible for alveolar bone. Images of trabeculae > 100 microns in diameter could be identified, but smaller ones could not be resolved. The Nyquist Criterion requires sampling with 50 microns (or smaller) pixels to measure such features. Numerous 25 microns Ag aggregates were present. Fifty microns resolution is a practical compromise between noise level and feature resolution. In another example of 10 bitewings digitized at 8 bit grey scale, about half the available range was used for alveolar bone, resulting in uncertainty, over a range of 2 optical density (OD) units, of about 1.42% at the average OD for alveolar bone (1.1). With the same radiographs digitized at 12 bit resolution, over 2000 of 4096 grey scales were used with a corresponding uncertainty of about 0.09%. Twelve-bit precision was also able to resolve smaller increments in an aluminium stepwedge than was 8 bit precision. Twelve-bit grey scale and 50 microns spatial resolution are recommended for alveolar bone densitometry performed with Ektaspeed radiographs.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
E. Sannomiya, M. Macedo, D. Siqueira, F. Goldenberg, and S Bommarito
Evaluation of optical density of the midpalatal suture 3 months after surgically assisted rapid maxillary expansion
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 97 - 101.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Fidler, B Likar, and U Skaleric
Lossy JPEG compression: easy to compress, hard to compare.
Dentomaxillofac. Radiol., March 1, 2006; 35(2): 67 - 73.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1994 by the British Institute of Radiology.