DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moystad, A.
Right arrow Articles by Grondahl, H. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moystad, A.
Right arrow Articles by Grondahl, H. G.

Dentomaxillofacial Radiology, Vol 23, Issue 4 206-210, Copyright © 1994 by British Institute of Radiology


ARTICLES

The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films

A. Moystad, D. B. Svanaes, T. A. Larheim and H. G. Grondahl
Department of Oral Radiology, Faculty of Dentistry, University of Oslo, Sweden.

Studies of observer performance with non-manipulated digital images are almost lacking; nor has the effect of cathode ray tube (CRT) display formats been evaluated. The present study compared the diagnostic accuracy of observers with and without clinical experience in evaluating intra-oral dental films and the corresponding non-manipulated digitized images. Three different-sized (5", 9", 17") monitors were used to study the effect of CRT display format. Artificial radiolucent and radiopaque lesions in dry human mandibles were examined. ROC curve areas were averaged and cross-tabulated according to viewing method and observer experience. For the total group, the non-manipulated digital images resulted in smaller ROC curve areas than the plain films for all CRT formats, with a significantly inferior result for the 17" images (p = 0.036). The increase in diagnostic accuracy of the digital images with decreasing CRT size was not significant (p > 0.05). There was some difference in the mean ROC curve areas between teachers and students, but the effect of the viewing methods was not significant. In terms of observer performance, the experienced observers demonstrated a reduced, and the inexperienced an increased, variability with the digital images compared with conventional film.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
A Kunzel, D Scherkowski, R Willers, and J Becker
Visually detectable resolution of intraoral dental films
Dentomaxillofac. Radiol., November 1, 2003; 32(6): 385 - 389.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1994 by the British Institute of Radiology.