| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Dentomaxillofacial Radiology, Vol 24, Issue 1 55-58, Copyright © 1995 by British Institute of Radiology
ARTICLES |
N. L. Frederiksen, B. W. Benson and T. W. Sokolowski
The Baylor College of Dentistry, Dallas, Texas.
The effective dose from computed tomography of the maxillofacial complex has been estimated and used for an assessment of risk. For each scan sequence 64 TLDs were placed in 27 selected sites in the upper portion of a tissue-equivalent human phantom to record the equivalent dose in radiosensitive organs/tissues. Equivalent doses ranged from 0.11 mSv (bone marrow, maxillary scan) to 20 mSv (salivary glands, mandibular scan). By the use of a calculation that included the salivary glands as part of the remainder, two contiguous 1 cm axial slices of the maxilla were found to result in an effective dose of 0.1 mSv, and four contiguous 1 cm axial slices of the mandible in an effective dose of 0.76 mSv. Effective doses of this magnitude represent a probability of stochastic effects of the order of 8 X 10(-6) and 56 X 10(-6) respectively.
This article has been cited by other articles:
![]() |
H. K. Looe, F. Eenboom, N. Chofor, A. Pfaffenberger, M. Steinhoff, A. Ruhmann, A. Poplawski, K. Willborn, and B. Poppe CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSES IN INTRAORAL AND PANORAMIC DENTAL RADIOLOGY FROM DOSE-AREA PRODUCT VALUES Radiat Prot Dosimetry, June 11, 2008; (2008) ncn172v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Kaeppler, M. Buchgeister, and S. Reinert Influence of the rotation centre in panoramic radiography Radiat Prot Dosimetry, January 1, 2008; 128(2): 239 - 244. [Abstract] [Full Text] [PDF] |
||||
![]() |
G Kaeppler, K Dietz, K Herz, and S Reinert Factors influencing the absorbed dose in intraoral radiography Dentomaxillofac. Radiol., December 1, 2007; 36(8): 506 - 513. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Looe, F. Eenboom, N. Chofor, A. Pfaffenberger, M. Sering, A. Ruhmann, A. Poplawski, K. Willborn, and B. Poppe Dose-area product measurements and determination of conversion coefficients for the estimation of effective dose in dental lateral cephalometric radiology Radiat Prot Dosimetry, April 1, 2007; 124(2): 181 - 186. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Lagravere, Y Fang, J Carey, R. Toogood, G. Packota, and P. Major Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000 Dentomaxillofac. Radiol., November 1, 2006; 35(6): 407 - 409. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Ekestubbe, H-G Grondahl, and B Molander Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose Dentomaxillofac. Radiol., September 1, 2003; 32(5): 322 - 326. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ludlow, L. Davies-Ludlow, and S. Brooks Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit Dentomaxillofac. Radiol., July 1, 2003; 32(4): 229 - 234. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |