Dentomaxillofacial Radiology, Vol 24, Issue 3 173-178, Copyright © 1995 by British Institute of Radiology


ARTICLES

Reproducibility of repeat bitewing radiographs determined by measurement of the distance between the amelocemental junction and the alveolar crest: an ex vivo study using human skulls

K. Bishop, P. M. Dummer, A. Kingdon and R. G. Newcombe
Department of Conservative Dentistry, University of Wales College of Medicine, Cardiff, UK.

OBJECTIVE: To assess the reproducibility of repeat bitewing radiographs. METHODS: Five right and left pairs of posterior bitewing radiographs were taken without the use of beam-aiming or film-holding devices in five dry skulls with complete dentitions. The amelocemental junction (ACJ) and alveolar crest (AC) of every interdental site was traced on projected radiographs and the linear distance between the ACF and AC determined. RESULTS: There was close concordance between the ability to read the ACJ on the approximal tooth surface and the AC. The overall readability of interdental sites was 71% although sites at the extremities of radiographs were often unreadable. Kappa analysis of the readability of alveolar bone height from repeat radiographs was 0.52. There were significant differences in the reproducibility of ACJ and AC measurements from repeated radiographs (p<0.001). Intra-examiner variability was significantly less (p<0.001) than that due to repeat radiography with no significant differences between sites. The standard deviation for all surfaces from repeat readings of the same radiographs was 0.12 mm compared with 0.51 mm from repeat radiography. CONCLUSIONS: In this study a freehand technique produced a degree of imprecision in readings of alveolar bone height from successive films of the same site. In clinical terms, a difference of more than 1.4 mm between pairs of serial measurements from the same site would have to occur in order to be certain that the difference was not measurement error but real bone loss.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
E. Munhoz, O Ferreira Junior, R. Yaedu, and J. Granjeiro
Radiographic assessment of impacted mandibular third molar sockets filled with composite xenogenic bone graft.
Dentomaxillofac. Radiol., September 1, 2006; 35(5): 371 - 375.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1995 by the British Institute of Radiology.