DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wakoh, M.
Right arrow Articles by Kuroyanagi, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wakoh, M.
Right arrow Articles by Kuroyanagi, K.

Dentomaxillofacial Radiology, Vol 24, Issue 4 211-214, Copyright © 1995 by British Institute of Radiology


ARTICLES

Perceptibility of defects in an aluminum test object: a comparison of the RVG-S and first generation VIXA systems with and without added niobium filtration

M. Wakoh, A. G. Farman, W. C. Scarfe, M. S. Kelly and K. Kuroyanagi
Health Sciences Center, University of Louisville, Kentucky, USA.

OBJECTIVE: To compare the first generation VIXA (Gendex, Milan, Italy) and the RVG-S (Trophy Radiologie, Vincennes, France) for detection of defects in an aluminium test object at various exposures both with and without added niobium filtration. METHODS: Images of a 7 mm aluminium test object with defects ranging from 0.1 to 1.5 mm with standardized projection geometry. Seven dentists acted as observers. Perceptibility curves were developed for both sensors under the various filtration conditions and exposures. RESULTS: At optimum exposures both the VIXA and the RVG-S permitted the same number of defects to be observed. The optimum exposures were similar for the two systems, but the dynamic range was greater for the RVG-S. Addition of niobium filtration did not appreciably alter the radiation dose required to perceive a given number of defects using either system. CONCLUSIONS: The two systems performed equally at optimum exposure when the dose is approximately the same irrespective of the presence or absence of niobium filtration. Beyond the optimal level, the RVG-S outperformed the VIXA system.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
X-Q Shi, G Li, K Yoshiura, and U Welander
Perceptibility curve test for conventional and colour-coded radiographs
Dentomaxillofac. Radiol., September 1, 2004; 33(5): 318 - 322.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
K Yoshiura, U Welander, W. McDavid, G Li, X-Q Shi, E Nakayama, M Shimizu, K Okamura, and S Kanda
Comparison of the psychophysical properties of various intraoral film and digital systems by means of the perceptibility curve test
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 98 - 102.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1995 by the British Institute of Radiology.