DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Scarfe, W. C.
Right arrow Articles by Farman, A. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Scarfe, W. C.
Right arrow Articles by Farman, A. G.

Dentomaxillofacial Radiology, Vol 24, Issue 4 215-220, Copyright © 1995 by British Institute of Radiology


ARTICLES

Measurement accuracy: a comparison of two intra-oral digital radiographic systems, RadioVisiography-S and FlashDent, with analog film

W. C. Scarfe, S. Norton and A. G. Farman
University of Louisville School of Dentistry, Kentucky, USA.

OBJECTIVES: To compare the accuracy of measurement algorithms incorporated into the software provided with two CCD-based digital radiographic systems and compare assessments using intra-oral film. METHODS: A test object with three radiopaque reference points was imaged using Ektaspeed intra-oral film, both with and without an overlaid 1 mm reference grid, the RVG-S, the measurement software of which overlays a 2 mm grid, and the FlashDent, which uses a mouse-driven cursor to estimate distances. Geometric factors, including source-to-object and receptor-to-object distances, vertical and horizontal cone angulation, and vertical angulation of receptor, were successively altered. Six viewers estimated vertical, horizontal and diagonal distances for each image. RESULTS: Increased source-to-object distance resulted in a 5-10% reduction in image dimensions, whereas increased receptor-to-object distance produced a magnification of 15-20% with all techniques. Increased vertical and horizontal cone angulation resulted in slight increases in magnification (0-5%) whereas greater receptor angulation resulted in noticeable magnification under all test conditions (10-15%). Estimated values for vertical, horizontal and diagonal measurements were approximately 5-10% higher than the actual dimensions, irrespective of the technique used. The FlashDent mouse-driven cursor system and direct measurement of distances from conventional film were more accurate in horizontal and diagonal dimension estimates than using an overlaid grid. Intra-observer and inter-observer differences were found for specific situations. CONCLUSION: The mouse-driven computerized measurement cursor and intra-oral film assessment using a ruler provided the most accurate, reliable and consistent dimensional measurements.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
H Kitagawa and A. Farman
Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector
Dentomaxillofac. Radiol., January 1, 2004; 33(1): 21 - 24.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1995 by the British Institute of Radiology.