DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goshima, T.
Right arrow Articles by Farman, A. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goshima, T.
Right arrow Articles by Farman, A. G.

Dentomaxillofacial Radiology, Vol 25, Issue 1 17-18, Copyright © 1996 by British Institute of Radiology


ARTICLES

Sensitometric response of the Sens-A-Ray, a charge-coupled imaging device, to changes in beam energy

T. Goshima, Y. Goshima, W. C. Scarfe and A. G. Farman
Division of Radiology & Imaging Sciences, School of Dentistry, University of Louisville, USA.

OBJECTIVES: To evaluate image density (pixel values) and image contrast due to variations in beam energy (kVp) for the Sens-A-Ray intra-oral radiographic sensor. METHOD: Images of an aluminium step wedge were made at 50, 70 and 90 kVp. Mean pixel values (with standard deviations) for representative attenuator thicknesses were measured using region-of-interest histogram analysis. Corresponding entrance doses were measured using a beryllium-windowed ionization chamber. RESULTS: The steepest response slopes were found with the lowest kVp settings; hence the CCD results mimic the behaviour of standard radiographic film, with the high contrast being found with low kVp. The entrance dose resulting in pixel saturation was less with low kVp than high kVp. It is suggested that this is due to the CCD receptor being most sensitive to X-ray photons of relatively low keV. CONCLUSION: While the kVp needs to be selected in relation to both tissue and receptor characteristics, it is possible to use low kVp techniques with the Sens-A-Ray without increasing the entrance dosage.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
Influence of tube potential setting and dose on the visibility of lesions in intraoral radiography
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 75 - 79.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
P. Doyle and L. Finney
Performance evaluation and testing of digital intra-oral radiographic systems
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 313 - 317.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
H Kitagawa and A. Farman
Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector
Dentomaxillofac. Radiol., January 1, 2004; 33(1): 21 - 24.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1996 by the British Institute of Radiology.