DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Camp, J. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Camp, J. J.

Dentomaxillofacial Radiology, Vol 25, Issue 1 42-47, Copyright © 1996 by British Institute of Radiology


ARTICLES

Histogram-matching and histogram-flattening contrast correction methods: a comparison

C. F. Hildebolt, R. K. Walkup, G. L. Conover, N. Yokoyama-Crothers, T. Q. Bartlett, M. W. Vannier, M. K. Shrout and J. J. Camp
Washington University, St. Louis, Missouri, USA.

OBJECTIVES: To compare the results or two methods of histogram matching and two methods of histogram flattening for their ability to correct for contrast variations in digital dental images. METHODS: A custom-built, aluminium stepwedge with 0.1, 0.5 and 1.0 mm steps was placed over Ektaspeed films and exposed for 0.06, 0.12 and 0.25 s, respectively. Radiographs were digitized at 50 microns spatial resolution and 12-bit contrast resolution. Contrast corrections were performed using Ruttimann et al.'s algorithm (1986) for one method of matching (RM) and flattening (RF) and Castleman's algorithm (1979) for the other method of matching (CM) and flattening (CF). Mean pixel grey-scale values were determined for each step. The 0.12 s exposure was considered to be the target image exposure. Absolute differences in pixel grey-scale values between the target images and the modified images were determined. RESULTS: The median values of the absolute differences in pixel grey-scale values between the target images and the contrast corrected images were: CM = 4.3; RM = 4.1; CF = 70.2 and RF = 70.2. CONCLUSION: Castleman's and Ruttimann's matching algorithms perform equally well in correcting digital image contrast. Histogram flattening was less effective.


This article has been cited by other articles:


Home page
Eur J OrthodHome page
S. Akyalcin, S. Hazar, P. Guneri, S. Gogus, and A. M. E. Erdinc
Extraction versus non-extraction: evaluation by digital subtraction radiography
Eur J Orthod, December 1, 2007; 29(6): 639 - 647.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1996 by the British Institute of Radiology.