DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moystad, A.
Right arrow Articles by Grondahl, H. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moystad, A.
Right arrow Articles by Grondahl, H. G.

Dentomaxillofacial Radiology, Vol 25, Issue 4 202-206, Copyright © 1996 by British Institute of Radiology


ARTICLES

Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film

A. Moystad, D. B. Svanaes, S. Risnes, T. A. Larheim and H. G. Grondahl
Department of Oral Radiology, Faculty of Dentistry, University of Oslo, Norway.

OBJECTIVES: To compare the accuracy of approximal caries detection using enhanced and unenhanced storage phosphor images and dental X-ray film. METHODS: Fifty premolar/molar teeth were exposed simultaneously under standardized conditions on storage phosphor (SP) image plates (Digora) and Ektaspeed film. The image files were transferred to a different platform for image processing. Using a five-point confidence scale, ten observers rated 95 approximal surfaces for caries in enamel and dentin with three image modalities: enhanced and unenhanced SP images and film. The observations were validated microscopically. Diagnostic accuracy was measured as the area beneath the ROC curve (Az). RESULTS: Enhanced SP images had significantly higher Az values in both enamel (Az = 0.819) and dentin (Az = 0.845) than unenhanced images and film. No significant differences were found in either enamel or dentin between unenhanced SP images (Az = 0.780 and Az = 0.789) and film (Az = 0.688 and Az = 0.793). CONCLUSION: Enhancement of storage phosphor images improved detection of approximal caries in this in vitro study compared with unenhanced images and Ektaspeed film.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
Z Z Akarslan, M Akdevelioglu, K Gungor, and H Erten
A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth
Dentomaxillofac. Radiol., December 1, 2008; 37(8): 458 - 463.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F Haiter-Neto, A Wenzel, and E Gotfredsen
Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
Dentomaxillofac. Radiol., January 1, 2008; 37(1): 18 - 22.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
E Alpoz, E Sogur, and B. Baksi Akdeniz
Perceptibility curve test for digital radiographs before and after application of various image processing algorithms
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 490 - 494.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
I Peker, M Toraman Alkurt, and B Altunkaynak
Film tomography compared with film and digital bitewing radiography for proximal caries detection
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 495 - 499.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
W. Berkhout, J. Verheij, K Syriopoulos, G Li, G. Sanderink, and P. van der Stelt
Detection of proximal caries with high-resolution and standard resolution digital radiographic systems
Dentomaxillofac. Radiol., May 1, 2007; 36(4): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
V. Castro, J. Katz, P. Hardman, A. Glaros, and P Spencer
In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries
Dentomaxillofac. Radiol., March 1, 2007; 36(3): 138 - 142.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
Diagnostic accuracy of in vitro panoramic radiographs depending on the exposure
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 68 - 74.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
K Yoshiura, E Nakayama, M Shimizu, T. Goto, T Chikui, T Kawazu, and K Okamura
Effects of the automatic exposure compensation on the proximal caries diagnosis
Dentomaxillofac. Radiol., May 1, 2005; 34(3): 140 - 144.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Moystad, D. Svanaes, P. van der Stelt, H-G Grondahl, A Wenzel, F. van Ginkel, B Kullendorff, H Hintze, and T. Larheim
Comparison of standard and task-specific enhancement of Digora(R) storage phosphor images for approximal caries diagnosis
Dentomaxillofac. Radiol., November 1, 2003; 32(6): 390 - 396.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1996 by the British Institute of Radiology.