DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wakoh, M.
Right arrow Articles by Kuroyanagi, K.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Wakoh, M.
Right arrow Articles by Kuroyanagi, K.

Dentomaxillofacial Radiology, Vol 26, Issue 4 225-229, Copyright © 1997 by British Institute of Radiology


ARTICLES

Sensitometric effects of varying the intensifying screens used with Agfa Dentus ST8G and RP6 panoramic radiographic films

M. Wakoh, A. G. Farman, W. C. Scarfe, H. Kitagawa and K. Kuroyanagi
Department of Oral and Maxillofacial Radiology, Tokyo Dental College, Chiba, Japan.

OBJECTIVES: To compare the sensitometric effects and information yield of varying the intensifying screens used with both Dentus ST8G and RP6 Agfa Gevaert, Dormagen, Germany panoramic radiographic films. MATERIAL AND METHODS: Four screen-film combinations were employed for each of the two film types. The screens used were blue fluorescing PX-III (Kasei Optonix, Tokyo, Japan) and Special (Siemens AG, Bensheim, Germany), as well as green fluorescing Lanex Regular (Eastman Kodak, Rochester, NY, USA) and Trimax T16 (3M, Mineapolis, Minnesota, USA). The density response for each screen-film combination was evaluated using the characteristic curves generated. Information yield, as determined by the radiographic detection of defects in an aluminium test object, was evaluated by nine observers. RESULTS: The characteristic curves for ST8G were different when green and blue fluorescing screens were used; however, those for RP6 varied little irrespective of the choice of intensifying screens. Observers were able to perceive defects at significantly lower radiation exposures for ST8G combined with green fluorescing screens compared with blue emitting screens. RP6 with all screen combinations provided similar image detail perceptibility at comparable exposures with ST8G with green-fluorescing screens. CONCLUSIONS: RP6 is suitable for use with either the spectrally matched blue emitting screens or green-emitting screens. ST8G radiographic film should always be matched to rare earth screens.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
The effect of dose reduction on the detection of anatomical structures on panoramic radiographs.
Dentomaxillofac. Radiol., July 1, 2006; 35(4): 271 - 277.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1997 by the British Institute of Radiology.