DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farman, T. T.
Right arrow Articles by Stewart, A. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farman, T. T.
Right arrow Articles by Stewart, A. V.

Dentomaxillofacial Radiology, Vol 27, Issue 1 36-40, Copyright © 1998 by British Institute of Radiology


ARTICLES

Charge-coupled device panoramic radiography: effect of beam energy on radiation exposure

T. T. Farman, A. G. Farman, M. S. Kelly, F. J. Firriolo, J. M. Yancey and A. V. Stewart
School of Dentistry, University of Louisville, Kentucky 40292, USA.

OBJECTIVE: To determine the consequences for entrance exposure of varying the beam energy and operating current for panoramic radiography using a charge-coupled device receptor. MATERIAL AND METHODS: Images were made of a RANDO average man phantom (Alderson Research Laboratories, Stamford, CT) at kVcp settings of 60, 66, 70 and 80 and an mA of 2.0, 3.2, 6.4 and 10.0. The exposure cycle was set as recommended by the manufacturer at 17.6 s. Diagnostic image quality was rated by a panel of two oral and maxillofacial radiologists and one oral and maxillofacial pathologist. Entrance exposures were assessed using a 3 cc ionization chamber placed at the beam entry points while imaging the molar, premolar, and anterior teeth both using the DigiPan (Trophy Radiologie, Vincennes, France) CCD receptor and conventional T-Mat G film/Lanex Regular screens (Eastman Kodak, Rochester, NY, USA). RESULTS: Acceptable image quality was attained with combinations of 60 kVcp and 3.2, 6.4 or 10 mA, 70 kVcp and 2.0, 3.2 or 6.4 mA; at 80 kVcp irrespective of the mA it was unacceptable. The maximum reduction in entrance dose was 77%, averaged over the three sites, at 70 kVcp and 2 mA. CONCLUSION: The DigiPan receptor produces satisfactory images with saving in entry exposure saving of approximately 70% when compared with a conventional film/rare earth screen combination.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
Diagnostic accuracy of in vitro panoramic radiographs depending on the exposure
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 68 - 74.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
Influence of tube potential setting and dose on the visibility of lesions in intraoral radiography
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 75 - 79.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
G Kaeppler, K Dietz, and S Reinert
The effect of dose reduction on the detection of anatomical structures on panoramic radiographs.
Dentomaxillofac. Radiol., July 1, 2006; 35(4): 271 - 277.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F Gijbels, R Jacobs, R Bogaerts, D Debaveye, S Verlinden, and G Sanderink
Dosimetry of digital panoramic imaging. Part I: patient exposure
Dentomaxillofac. Radiol., May 1, 2005; 34(3): 145 - 149.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, A Thilander-Klang, A Lith, and H-G Grondahl
Effective and organ doses from scanography and zonography: a comparison with periapical radiography
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 87 - 92.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
B Molander, H-G Grondahl, and A Ekestubbe
Quality of film-based and digital panoramic radiography
Dentomaxillofac. Radiol., January 1, 2004; 33(1): 32 - 36.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, H-G Grondahl, and B Molander
Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose
Dentomaxillofac. Radiol., September 1, 2003; 32(5): 322 - 326.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.