DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yoshiura, K.
Right arrow Articles by Tronje, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yoshiura, K.
Right arrow Articles by Tronje, G.

Dentomaxillofacial Radiology, Vol 27, Issue 3 131-135, Copyright © 1998 by British Institute of Radiology


ARTICLES

The perceptibility curve test applied to direct digital dental radiography

K. Yoshiura, H. Stamatakis, X. Q. Shi, U. Welander, W. D. McDavid, J. Kristoffersen and G. Tronje
Department of Oral Radiology, Karolinska Institutet, Stockholm, Sweden.

OBJECTIVE: To compare the effect of an additional scintillator layer on the psychophysical properties of a CCD detector for digital dental radiography. METHODS: Radiographs of a test object containing ten holes of increasing depth were obtained throughout the exposure range of two CCD detectors at 70 and 90 kVp. One was the original detector for the Sens-A-Ray system (Regam Medical Systems, Sundsvall, Sweden) and the other the same detector covered by a scintillator layer. Ten viewers evaluated the radiographs for the number of perceptible holes. From these data and the dose response functions for the two detectors, the minimum perceptible exposure difference was found. The reciprocal values of this parameter were plotted against the logarithm of exposure to create Perceptibility Curves (PCs). RESULTS: The four PCs had essentially the same shape and height. There was a shift to lower exposures in the PCs for the detector covered by a scintillator. CONCLUSIONS: The two detectors have essentially the same psychophysical properties. Since the detector covered by a scintillator layer is more sensitive, it should be preferred for clinical practice since the dose to the patient is reduced.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
X-Q Shi, G Li, K Yoshiura, and U Welander
Perceptibility curve test for conventional and colour-coded radiographs
Dentomaxillofac. Radiol., September 1, 2004; 33(5): 318 - 322.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
M Mastoris, K Yoshiura, U Welander, K Tsiklakis, E Papadakis, and G Li
Psychophysical properties of a new F-speed intraoral film
Dentomaxillofac. Radiol., May 1, 2004; 33(3): 158 - 163.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
K Yoshiura, U Welander, W. McDavid, G Li, X-Q Shi, E Nakayama, M Shimizu, K Okamura, and S Kanda
Comparison of the psychophysical properties of various intraoral film and digital systems by means of the perceptibility curve test
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 98 - 102.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
G Li, U Welander, K Yoshiura, X-Q Shi, and W. McDavid
Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response
Dentomaxillofac. Radiol., November 1, 2003; 32(6): 372 - 378.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
K Yoshiura, U Welander, W. McDavid, G Li, X-Q Shi, T Kawazu, M Tatsumi, T Matsuo, and S Kanda
Perceptibility curves for the Digora system
Dentomaxillofac. Radiol., May 1, 2003; 32(3): 191 - 197.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.