DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Shrout, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hildebolt, C. F.
Right arrow Articles by Shrout, M. K.

Dentomaxillofacial Radiology, Vol 27, Issue 4 245-250, Copyright © 1998 by British Institute of Radiology


ARTICLES

Comparison of reliability of manual and computer-intensive methods for radiodensity measures of alveolar bone loss

C. F. Hildebolt, B. Brunsden, N. Yokoyama-Crothers, T. K. Pilgram, K. E. Townsend, M. W. Vannier and M. K. Shrout
Washington University, St. Louis, USA .

OBJECTIVE: To compare the reliability of radiodensity measurements made from dental radiographs with manual and a novel computer-intensive methods. METHODS: As part of a prospective study of postmenopausal women, a series of seven vertical bitewing radiographs were taken of 36 patients. One of each set of radiographs was repeated. The original and the corresponding duplicate radiographs were used in this study. Radiographs were digitized at 50 microns spatial resolution and 12-bit gray-scale resolution. For the Manual Method, original and duplicate radiographs were manually cropped to improve image homology, histogram matched and mean pixel gray-scale values determined for an alveolar bone ROI within each image. For the computer-intensive method, images were put into registration with ANALYZE software (Mayo Foundation, Rochester, MINN, USA), cropped automatically, histogram matched and color-coded on the basis of the per cent difference. Alveolar bone ROIs adjacent to clinical crowns and root surfaces whose color code indicated less than a 5% change were sampled. Method error (ME) and the coefficient of variation of method error (CVME) were calculated. RESULTS: With the Manual Method the SD between original and duplicate measures was 95.21 out of 4096 gray scale values; ME = 67.32; CVME = 3.78%. For the computer-intensive method, the corresponding values were 54.74, 38.71, and 2.29%. CONCLUSIONS: The new computer-intensive method resulted in a 40% improvement over the Manual Method in the precision of radiodensity measurements.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
P Guneri, S Gogus, Z Tugsel, A Ozturk, C Gungor, and H Boyacioglu
Clinical efficacy of a new software developed for dental digital subtraction radiography
Dentomaxillofac. Radiol., November 1, 2006; 35(6): 417 - 421.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
R. Civitelli, T. K. Pilgram, M. Dotson, J. Muckerman, N. Lewandowski, R. Armamento-Villareal, N. Yokoyama-Crothers, E. E. Kardaris, J. Hauser, S. Cohen, et al.
Alveolar and Postcranial Bone Density in Postmenopausal Women Receiving Hormone/Estrogen Replacement Therapy: A Randomized, Double-blind, Placebo-Controlled Trial
Arch Intern Med, June 24, 2002; 162(12): 1409 - 1415.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.