DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cederberg, R. A.
Right arrow Articles by Shulman, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cederberg, R. A.
Right arrow Articles by Shulman, J. D.

Dentomaxillofacial Radiology, Vol 27, Issue 5 293-297, Copyright © 1998 by British Institute of Radiology


ARTICLES

Effect of different background lighting conditions on diagnostic performance of digital and film images

R. A. Cederberg, N. L. Frederiksen, B. W. Benson and J. D. Shulman
Baylor College of Dentistry/Texas A&M University System Dallas, USA.

OBJECTIVE: To compare the performance of a photostimulable phosphor (PSP) imaging system with radiographic film for the detection of approximal lesions under two background lighting conditions. METHODS: Bitewing exposures were made of the extracted human teeth with artificial approximal lesions using D-speed and E-speed radiographic film and a PSP imaging plate. Eight dentists rated 12 approximal surfaces in each image on a 5-point scale. Images were viewed with overhead fluorescent room lighting on and off. ROC curves were generated for each image receptor and lighting condition. Repeated measures analysis of variance ANOVA tested differences between observers, lesion size, image receptor, lighting condition. RESULTS: Mean ROC curve areas for D-speed film viewed in full ambient light scored highest (0.8030) followed by E-speed film using dark conditions (0.7386). The lowest mean curve area was found when PSP (enhanced mode) images were viewed in a dark room (0.6726). Significant differences were found between observers, lesion size, image receptor and image receptor-lesion size interaction. No significant difference was found with background lighting. CONCLUSIONS: Background lighting does not appear to effect the ability to detect artificial approximal lesions.


This article has been cited by other articles:


Home page
Journal of the American Dental AssociationHome page
L. L. OTIS and R. G. SHERMAN
Assessing the accuracy of caries diagnosis via radiograph: Film versus print
J Am Dent Assoc, March 1, 2005; 136(3): 323 - 330.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
Digitized conventional radiograph
Dentomaxillofac. Radiol., November 1, 2004; 33(6): 420 - 421.
[Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
R Goga, N. Chandler, and R. Love
Clarity and diagnostic quality of digitized conventional intraoral radiographs
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 103 - 107.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Kunzel, D Scherkowski, R Willers, and J Becker
Visually detectable resolution of intraoral dental films
Dentomaxillofac. Radiol., November 1, 2003; 32(6): 385 - 389.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. H. Fuchsjager, C. M. Schaefer-Prokop, E. Eisenhuber, P. Homolka, M. Weber, M. A. Funovics, and M. Prokop
Impact of Ambient Light and Window Settings on the Detectability of Catheters on Soft-Copy Display of Chest Radiographs at Bedside
Am. J. Roentgenol., November 1, 2003; 181(5): 1415 - 1421.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.