DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cavalcanti, M. G.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cavalcanti, M. G.
Right arrow Articles by Vannier, M. W.

Dentomaxillofacial Radiology, Vol 27, Issue 6 329-333, Copyright © 1998 by British Institute of Radiology


ARTICLES

Validation of spiral computed tomography for dental implants

M. G. Cavalcanti, J. Yang, A. Ruprecht and M. W. Vannier
Department of Radiology, Faculty of Odontology, University of Sao Paulo, Brazil.

OBJECTIVES: To investigate the accuracy of 2DCT orthoradial reformatted images from spiral computed tomography (CT) for pre-surgical planning of dental implants in proximity to the mental foramen. METHODS: Eight cadaver heads were imaged by spiral CT (S/Xpress, Toshiba-America, Tustin, CA) with 1 mm thick axial slices by 1 mm/sec of table feed. The image data set was transferred to a networked computer workstation. Using computer graphics the data was analysed with 2D orthoradial reformatting using the ToothPix (Cemax, Fremont, CA, USA) protocol. Linear measurements were made by two oral radiologists independently from the superior border of the mental foramen to the crest of the alveolar process and from the inferior border of the mental foramen to the mandibular inferior border. The soft tissues were removed and physical measurements made using a 3 Space (Polhemus, Colchester, VT) electromagnetic digitizer with a personal computer running Windows 95. RESULTS: The differences between the measurements on orthoradial 2DCT images and the physical measurements were not statistically significant (P > 0.05). CONCLUSIONS: Two-dimensional spiral CT imaging allows highly accurate measurements for dental implant placement in proximity to the mental foramen. Computer graphics software, using reformatted reconstruction, is suitable for implant planning.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
A. Suomalainen, A Salo, S Robinson, and J. Peltola
The 3DX multi image micro-CT device in clinical dental practice
Dentomaxillofac. Radiol., February 1, 2007; 36(2): 80 - 85.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
J. Dantas, A Montebello Filho, and P. Campos
Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and width
Dentomaxillofac. Radiol., January 1, 2005; 34(1): 9 - 15.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.