DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cavalcanti, M. G.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cavalcanti, M. G.
Right arrow Articles by Vannier, M. W.

Dentomaxillofacial Radiology, Vol 27, Issue 6 344-350, Copyright © 1998 by British Institute of Radiology


ARTICLES

Quantitative analysis of spiral computed tomography for craniofacial clinical applications

M. G. Cavalcanti and M. W. Vannier
Department of Radiology, Faculty of Odontology, University of Sao Paulo, Brazil.

OBJECTIVE: To determine the relative accuracy of craniofacial measurements obtained from volumetric spiral computed tomography (CT) in two-dimensional (2D) and three-dimensional (3D) reconstructions. MATERIALS AND METHODS: Nine cadaver heads were examined with spiral CT at 3 mm collimation with 2 mm/s table feed. The CT data, stored on optical disks to allow full retrospective review of any image, were transferred to a networked computer workstation for off-line visualization, measurement and analysis. Three-dimensional surface images (3DCT) were generated from spiral CT scans (2DCT). Measurements (n = 28) were made from (both unique and conventional craniometric anatomical) landmarks (n = 23) identified in 2DCT and 3DCT images by two observers twice. The soft tissues were then removed from the cadavers and the measurements performed with an electromagnetic digitizer. RESULTS: The accuracy for 3DCT was higher than 2DCT images for seven of 28 measurements. Twenty five per cent of the 2DCT measurements were found to be significantly different from the physical measurements. All measurements with 3DCT were found to have satisfactory accuracy in comparison with physical measurements. CONCLUSIONS: Three-dimensional spiral CT can distinguish craniofacial anatomy more accurately with some measurements.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
S. Connor, T Arscott, J Berry, L Greene, and R O'Gorman
Precision and accuracy of low-dose CT protocols in the evaluation of skull landmarks
Dentomaxillofac. Radiol., July 1, 2007; 36(5): 270 - 276.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F. Draenert, E Coppenrath, P Herzog, S Muller, and U. Mueller-Lisse
Beam hardening artefacts occur in dental implant scans with the NewTom(R) cone beam CT but not with the dental 4-row multidetector CT
Dentomaxillofac. Radiol., May 1, 2007; 36(4): 198 - 203.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
C. Lascala, J Panella, and M. Marques
Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
Dentomaxillofac. Radiol., September 1, 2004; 33(5): 291 - 294.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
M. Cavalcanti, S. Rocha, and M. Vannier
Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications
Dentomaxillofac. Radiol., May 1, 2004; 33(3): 170 - 176.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1998 by the British Institute of Radiology.