DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Syriopoulos, K.
Right arrow Articles by van der Stelt, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Syriopoulos, K.
Right arrow Articles by van der Stelt, P. F.

Dentomaxillofacial Radiology, Vol 28, Issue 4 208-213, Copyright © 1999 by British Institute of Radiology


ARTICLES

The effect of developer age on the detection of approximal caries using three dental films

K. Syriopoulos, X. L. Velders, G. C. Sanderink, F. C. van Ginkel, J. P. van Amerongen and P. F. van der Stelt
Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), The Netherlands.

OBJECTIVES: To compare the diagnostic accuracy for the detection of approximal caries of three dental X-ray films using fresh and aged processing chemicals. METHODS: Fifty-six extracted unrestored premolars were radiographed under standardized conditions using the new Dentus M2 (Agfa-Gevaert, Mortsel, Belgium), Ektaspeed Plus and Ultra-speed (Kodak Eastman Co, Rochester, USA) dental films. The films were processed manually using Agfa chemicals (Heraeus Kulzer, Dormagen, Germany). The procedure was repeated once a week until the complete exhaustion of the chemicals (6 weeks). Three independent observers assessed 210 radiographs using the following rating scale: 0 = sound, 1 = enamel lesion; 2 = lesion reaching the ADJ; 3 = dentinal lesion. True caries depth was determined by histological examination (14 sound surfaces, 11 enamel lesions, eight lesions reaching the ADJ and 23 dentinal lesions). True caries depth was subtracted from the values given by the observers and an analysis of variance was performed. The null hypothesis was rejected when P < 0.05. RESULTS: No significant differences were found in the diagnostic accuracy between the three films when using chemicals of up to 3 weeks old (P = 0.056). After the third week, Ultra-speed was significantly better than the other two films (P = 0.012). On average caries depth was underestimated. CONCLUSION: A similar level of diagnostic accuracy for approximal caries is achieved when using the three films. Dentus M2 and Ektaspeed Plus are at present the fastest available films and they should therefore be recommended for clinical practice. Agfa chemicals should be renewed every 3 weeks. Fifty per cent reduction in average gradient is indicative of renewing processing chemicals.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
I Peker, M Toraman Alkurt, and B Altunkaynak
Film tomography compared with film and digital bitewing radiography for proximal caries detection
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 495 - 499.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
M. Casanova and F Haiter-Neto
Effects of developer depletion on image quality of Kodak Insight and Ektaspeed Plus films
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 108 - 113.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1999 by the British Institute of Radiology.