DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liang, H.
Right arrow Articles by Lang, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liang, H.
Right arrow Articles by Lang, L. A.

Dentomaxillofacial Radiology, Vol 28, Issue 4 232-237, Copyright © 1999 by British Institute of Radiology


ARTICLES

Cross-sectional presurgical implant imaging using tuned aperture computed tomography (TACT)

H. Liang, D. A. Tyndall, J. B. Ludlow and L. A. Lang
Department of Diagnostic Sciences and General Dentistry, School of Dentistry, University of North Carolina at Chapel Hill, USA.

OBJECTIVES: To investigate tuned aperture computed tomography (TACT) as an alternative to conventional tomography for cross-sectional imaging of potential implant sites. METHODS: Twenty potential implant sites in three dry human mandibles were selected. Sixteen TACT basis projections were recorded on film using a linear array of source positions. Films were scanned and 20 TACT and iterative TACT slices were reconstructed using TACT Workbench software. Maximum height and width were measured on one representative slice of each site. Results were compared with the ground truth using ANOVA and Wilcoxon signed rank tests. RESULTS: The means of relative difference in maximum height were 1.55 and 1.56% for TACT and iterative TACT respectively (P = 0.8643). The means of relative difference in width were 5.96 and 6.36% for TACT and iterative TACT respectively (P = 0.4845). More than 75% measurements were within +/- 1 mm of ground truth for both modalities. CONCLUSIONS: TACT may provide an alternative to conventional tomography for dental implant imaging. Further investigations should be performed to explore factors affecting image quality.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
M Abreu Jr, L Yi-Ching, and A. Abreu
Comparative diagnostic performance of TACT(R) slices and its multiple source images: an in vitro study
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 93 - 97.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1999 by the British Institute of Radiology.