DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stamatakis, H. C.
Right arrow Articles by McDavid, W. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stamatakis, H. C.
Right arrow Articles by McDavid, W. D.

Dentomaxillofacial Radiology, Vol 28, Issue 5 272-276, Copyright © 1999 by British Institute of Radiology


ARTICLES

Dose response of a storage phosphor system for intraoral radiography

H. C. Stamatakis, U. Welander and W. D. McDavid
Department of Oral Radiology, Karolinska Institutet, Stockholm, Sweden.

OBJECTIVES: To determine the dose response function for the Digora(R) (Soredex Orion Corporation, Helsinki, Finland) storage phosphor system for intra-oral radiography. METHODS: Specially designed software provided by the manufacturer was used to register data from the pre-scanning that takes place prior to readout. These data contain information about the signal from the photomultiplier and the amplification that forms the basis for the AD conversion to 8 bit image data. Dose response functions were determined for different calibration settings and also combined into one single function. RESULTS: The dose response function is linear irrespective of calibration. The gray levels of the final radiographs are directly proportional to the amplified signal. The Digora(R) does not fully compensate for exposure differences. Increased exposure results in slightly darker radiographs. CONCLUSIONS: Since the gray levels of the final radiographs are directly proportional to the amplified signal, the gray levels may be used as a relative measure of the exposure in the Digora(R) system provided that they are subtracted from the maximum value of 255.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
K Yoshiura, U Welander, W. McDavid, G Li, X-Q Shi, T Kawazu, M Tatsumi, T Matsuo, and S Kanda
Perceptibility curves for the Digora system
Dentomaxillofac. Radiol., May 1, 2003; 32(3): 191 - 197.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1999 by the British Institute of Radiology.