DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yoshiura, K.
Right arrow Articles by Kanda, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yoshiura, K.
Right arrow Articles by Kanda, S.

Dentomaxillofacial Radiology, Vol 28, Issue 5 277-283, Copyright © 1999 by British Institute of Radiology


ARTICLES

Physical evaluation of a system for direct digital intra-oral radiography based on a charge-coupled device

K. Yoshiura, H. C. Stamatakis, U. Welander, W. D. McDavid, X. Q. Shi, S. Ban, T. Kawazu, M. Tatsumi and S. Kanda
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Kyushu University, Fukuoka, Japan.

OBJECTIVES: To determine technical properties of a direct digital intra-oral radiographic system, the Dixel(R) (J Morita Corporation, Kyoto, Japan). METHODS: A dose response function and the dark current were calculated from two series of exposures to a homogeneous radiation field. The line spread function (LSF) and the modulation transfer function (MTF) were determined from radiographs of an edge. The noise power spectrum (NPS) was determined at three exposures from radiographs exposed to homogeneous radiation fields. Noise equivalent quanta (NEQ) were calculated from the one-dimensional NPS and the MTF. The detective quantum efficiency (DQE) was determined from the NEQ and a representative value of the photon fluence. Signal-to-noise ratios (SNR) were calculated from the NEQs and different signal contrasts. RESULTS: The dose response function demonstrated a slight curvature. There was no effect of the dark current. NPS ranged from 10-5 - 10-7 mm2 depending on exposure and frequency. At a peak of about 2 cycles/mm the DQE is on an average about 30 per cent. SNRs are favorable. CONCLUSION: The technical properties found in this study indicate that the Dixel(R) system is suitable for intra-oral dental radiography.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 1999 by the British Institute of Radiology.