DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nair, M. K.
Right arrow Articles by Johnson, M. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nair, M. K.
Right arrow Articles by Johnson, M. P.

Dentomaxillofacial Radiology, Vol 29, Issue 5 297-301, Copyright © 2000 by British Institute of Radiology


ARTICLES

Comparative evaluation of Tuned Aperture Computed Tomography for the detection of mandibular fractures

M. K. Nair, R. L. Webber and M. P. Johnson
Department of Oral and Maxillofacial Radiology, University of Pittsburgh School of Dental Medicine, Pittsburgh, Pennsylvania, USA.

OBJECTIVES: To compare the diagnostic efficacy of Tuned Aperture Computed Tomography (TACT) with conventional imaging modalities for detection of fractures of the mandible. METHODS: Fractures were induced using blunt trauma in human defleshed mandibles. Conventional extra-oral and indirect digital images, unprocessed TACT images reconstructed from eight and 16 basis images (BI) and iteratively restored TACT images from eight and 16 BI were used for fracture evaluation. Twelve observers recorded their diagnoses using a five-point confidence rating scale. The data were analysed using ROC curve analysis. RESULTS: Significant differences were found (P < 0.0001) in the areas under the curve (Az): film, 0.6954; digital images 0.6169; TACT unprocessed images using 8 BI, 0.7420; TACT unprocessed images using 8 BI, 0.7667; TACT unprocessed images using 16 BI, 0.7730; TACT iteratively restored images using 16 BI, 0.8143. No observer-based differences were found. Fractures in the condylar and coronoid regions were more difficult to detect than those in the ramus and body of the mandible. CONCLUSIONS: Iteratively restored TACT images generated using 16 BI had a superior diagnostic performance to all the other imaging modalities. Studies are in order to evaluate its in vivo potential.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
M Abreu Jr, L Yi-Ching, and A. Abreu
Comparative diagnostic performance of TACT(R) slices and its multiple source images: an in vitro study
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 93 - 97.
[Abstract] [Full Text] [PDF]


Home page
J. Dent. Res.Home page
A. Wenzel
Two Decades of Computerized Information Technologies in Dental Radiography
J. Dent. Res., September 1, 2002; 81(9): 590 - 593.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2000 by the British Institute of Radiology.