DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gijbels, F.
Right arrow Articles by Jacobs, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gijbels, F.
Right arrow Articles by Jacobs, R.

Dentomaxillofacial Radiology, Vol 30, Issue 2 101-105, Copyright © 2001 by British Institute of Radiology


ARTICLES

Diagnostic yield of conventional and digital cephalometric images: a human cadaver study

F. Gijbels, C. Bou Serhal, G. Willems, H. Bosmans, G. Sanderink, M. Persoons and R. Jacobs
Oral Imaging Cluster, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.

OBJECTIVES: To compare the clinical efficacy of digital and conventional cephalometric imaging. METHODS: Conventional and photostimulable phosphor cephalometric radiographs were obtained from three human cadavers at nine different exposure settings. Subjective image quality was assessed by six observers who evaluated six cephalometric landmarks. Organ doses were measured with TLDs and effective doses calculated. RESULTS: Compared with conventional cephalometric images, digital images had a consistently better subjective image quality for all exposure settings which was significant (P<0.05) for all but two. Organ doses were comparable. Higher kV and lower mAs settings yielded the lowest effective dose, which was highly dependent on the position of the thyroid gland in the beam. CONCLUSION: Relatively small variations in exposure settings do not influence subjective diagnostic image quality of digital cephalometric radiographs. Higher kV and lower mAs settings have the lowest effective dose and should therefore be preferred.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
Y-J Chen, S-K Chen, H-W Huang, C-C Yao, and H-F Chang
Reliability of landmark identification in cephalometric radiography acquired by a storage phosphor imaging system
Dentomaxillofac. Radiol., September 1, 2004; 33(5): 301 - 306.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F Gijbels, G Sanderink, J Wyatt, J Van Dam, B Nowak, and R Jacobs
Radiation doses of collimated vs non-collimated cephalometric exposures
Dentomaxillofac. Radiol., March 1, 2003; 32(2): 128 - 133.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2001 by the British Institute of Radiology.