DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gijbels, F.
Right arrow Articles by Jacobs, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gijbels, F.
Right arrow Articles by Jacobs, R.

Dentomaxillofacial Radiology, Vol 30, Issue 6 308-313, Copyright © 2001 by British Institute of Radiology


ARTICLES

Organ doses and subjective image quality of indirect digital panoramic radiography

F. Gijbels, G. Sanderink, C. B. Serhal, H. Pauwels and R. Jacobs
Oral Imaging Cluster, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.

OBJECTIVES: To determine if slight variations in exposure will affect diagnostic image quality and absorbed radiation doses for digital and analogue panoramic radiography. METHODS: Thermoluminescent dosimeters were placed in the thyroid gland, eyes, submandibular glands, parotid glands and skin of two human cadaver heads. Three different exposure settings were used: 70 kV, 120 mAs; 77 kV, 75 mAs; and 81 kV, 60 mAs. Subjective image quality was assessed using a phantom head. Storage phosphor (SP) images were printed on film and both analogue and SP images were assessed for their subjective image quality on a five-point rating scale. The results were statistically analysed using logistic regression analysis and chi(2) tests. RESULTS: Highest organ doses were measured for the submandibular glands, followed by the parotid glands. Salivary gland doses tended to be higher at lower kV settings. Image quality was not statistically different for the different exposure settings. Imaging technique did not seem to influence diagnostic image quality, except for the periapical status of upper premolars where SP was better. The main reason for any differences appeared to be interobserver variation. CONCLUSIONS: Analogue and SP panoramic radiography performed equally well for subjective diagnostic image quality. No significant differences could be found at the exposure settings used in this study. Radiation doses were highest for the salivary glands, especially at lower kV settings.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, A Thilander-Klang, A Lith, and H-G Grondahl
Effective and organ doses from scanography and zonography: a comparison with periapical radiography
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 87 - 92.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
B Molander, H-G Grondahl, and A Ekestubbe
Quality of film-based and digital panoramic radiography
Dentomaxillofac. Radiol., January 1, 2004; 33(1): 32 - 36.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Ekestubbe, H-G Grondahl, and B Molander
Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose
Dentomaxillofac. Radiol., September 1, 2003; 32(5): 322 - 326.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
I. Benediktsdottir, H Hintze, J. Petersen, and A Wenzel
Accuracy of digital and film panoramic radiographs for assessment of position and morphology of mandibular third molars and prevalence of dental anomalies and pathologies
Dentomaxillofac. Radiol., March 1, 2003; 32(2): 109 - 115.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2001 by the British Institute of Radiology.