DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramesh, A.
Right arrow Articles by Paquette, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramesh, A.
Right arrow Articles by Paquette, D.

Dentomaxillofacial Radiology, Vol 30, Issue 6 319-324, Copyright © 2001 by British Institute of Radiology


ARTICLES

Evaluation of tuned aperture computed tomography (TACT) in the localization of simulated periodontal defects

A. Ramesh, J. B. Ludlow, R. L. Webber, D. A. Tyndall and D. Paquette
Tufts University School of Dental Medicine, Department of General Dentistry, Division of Oral and Maxillofacial Radiology, Boston, MA 02111, USA. Aruna.Ramesh@tufts.edu

OBJECTIVES: To compare the diagnostic efficacy of tuned aperture computed tomography (TACT) with the application of the 'buccal object rule' (BOR) in the localization of simulated periodontal defects. METHODS: Thirty interproximal sites were selected in fifteen cadaver segments of maxillae and mandible. Artificial periodontal defects were created using round burs and 40% formic acid in the buccal, lingual or mid-buccolingual areas. Eight basis projections were obtained and TACT slices were reconstructed for each region of interest. Two of the basis images were used in application of BOR for localization of the defect. Eight observers scored the location of defects using TACT slices and the paired radiographs separately. Data were analysed using the kappa statistic and ANOVA. RESULTS: A mean weighted kappa of 0.14 for localization was obtained with both BOR and TACT. Using ANOVA, there was no significant difference between modality and observer. There was however, a significant difference (P=0.019) between different defect sizes. Both modalities performed better with larger defect sizes. TACT performed slightly better than BOR when the smaller lesions were included; however, with larger lesions, this trend was reversed. CONCLUSIONS: The results confirm the relationship between correlation distance (the resultant slice width) and object size in the application of TACT for localization. BOR remains a simple yet effective tool for localization. The clinical significance is not clear considering the low kappa scores obtained with both the modalities.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
M Abreu Jr, L Yi-Ching, and A. Abreu
Comparative diagnostic performance of TACT(R) slices and its multiple source images: an in vitro study
Dentomaxillofac. Radiol., March 1, 2004; 33(2): 93 - 97.
[Abstract] [Full Text] [PDF]