| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Dentomaxillofacial Radiology, Vol 31, Issue 1 50-55, Copyright © 2002 by British Institute of Radiology
ARTICLES |
B. Dannewitz, S. Hassfeld, P. Eickholz and J. Muhling
Section of Peridontology, Department of Operative Dentistry and Periodontology, School of Dental Medicine, Ruprecht-Karls-University Heidelberg, 69120 Heidelberg, Germany.
OBJECTIVES: To investigate the effect of dose reduction in digital panoramic radiography on subjective image quality and diagnostic performance. METHODS: Two digital panoramic radiographs were obtained with the Orthophos DS(Sirona, Bensheim, Germany) of patients (n=100) receiving dental care. The first image was taken at the standard exposure setting. For the second image the tube current was reduced by between 48 and 53%, 63 and 69%, 75 and 80% and 80 and 81% respectively. Ten observers rated both images for 21 specific anatomical details and 30 pathological findings. RESULTS: All radiographs taken at reduced mA levels had a significantly inferior score (P<0.01) for anatomical details. There was no difference in the scores for pathological findings. CONCLUSION: Radiographs obtained at reduced mA had inferior subjective image quality, but there was no difference in diagnostic performance. Thus, a reduction in tube current of approximately 50% is recommended. In certain circumstances such as follow-up radiographic examinations, a reduction of up to 65% should be considered.
This article has been cited by other articles:
![]() |
G Kaeppler, K Dietz, and S Reinert The effect of dose reduction on the detection of anatomical structures on panoramic radiographs. Dentomaxillofac. Radiol., July 1, 2006; 35(4): 271 - 277. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Gijbels, R Jacobs, R Bogaerts, D Debaveye, S Verlinden, and G Sanderink Dosimetry of digital panoramic imaging. Part I: patient exposure Dentomaxillofac. Radiol., May 1, 2005; 34(3): 145 - 149. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Ekestubbe, A Thilander-Klang, A Lith, and H-G Grondahl Effective and organ doses from scanography and zonography: a comparison with periapical radiography Dentomaxillofac. Radiol., March 1, 2004; 33(2): 87 - 92. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Ekestubbe, H-G Grondahl, and B Molander Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose Dentomaxillofac. Radiol., September 1, 2003; 32(5): 322 - 326. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Benediktsdottir, H Hintze, J. Petersen, and A Wenzel Accuracy of digital and film panoramic radiographs for assessment of position and morphology of mandibular third molars and prevalence of dental anomalies and pathologies Dentomaxillofac. Radiol., March 1, 2003; 32(2): 109 - 115. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |