DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haak, R.
Right arrow Articles by Noack, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haak, R.
Right arrow Articles by Noack, M. J.

Dentomaxillofacial Radiology, Vol 31, Issue 3 193-197, Copyright © 2002 by British Institute of Radiology


ARTICLES

Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display

R. Haak, M. J. Wicht, M. Hellmich, G. Nowak and M. J. Noack
Department of Operative Dentistry and Periodontology, University of Cologne, Koln, Germany. Rainer.Haak@medizin.uni-koeln.de

OBJECTIVES: To determine the influence of ambient lighting on grey-scale perception using a cathode-ray tube (CRT) and a thin film transistor (TFT) computer display. METHODS: A cathode ray tube (Nokia XS 446) and a liquid crystal display (Panasonic LC 50S) were used at reduced room lighting (70 lux) and under conditions recommended for a dental operatory (1000 lux). Twenty-seven observers examined twice a modified SMPTE test pattern [0 to 255; 255 to 0] grey-scale values. The corresponding contrast differences were allocated to four ranges of grey levels (I: 0-63; II: 64-127; III: 128-191; IV: 192-255). The influences of monitor type, grey-scale range and illumination were evaluated by means of repeated measures analysis of variance. RESULTS: Detection of differences in monochromatic intensity was significantly earlier with reduced lighting (P<0.0001). When full ambient lighting was used, the TFT display was superior compared to the CRT monitor in ranges II and III (P<0.0001), whereas no differences could be detected for grey intensities between 0 and 63 (P=0.71) and between 192 and 255 (P=0.36). CONCLUSIONS: Background lighting hampers grey-scale perception on computer displays. In this study of one TFT and one CRT monitor, the TFT in full ambient lighting was associated with earlier detection of grey scale differences than CRT.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
K Hellen-Halme, M Nilsson, and A Petersson
Digital radiography in general dental practice: a field study
Dentomaxillofac. Radiol., July 1, 2007; 36(5): 249 - 255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Balassy, M. Prokop, M. Weber, J. Sailer, C. J. Herold, and C. Schaefer-Prokop
Flat-Panel Display (LCD) Versus High-Resolution Gray-Scale Display (CRT) for Chest Radiography: An Observer Preference Study
Am. J. Roentgenol., March 1, 2005; 184(3): 752 - 756.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Scharitzer, M. Prokop, M. Weber, M. Fuchsjager, E. Oschatz, and C. Schaefer-Prokop
Detectability of Catheters on Bedside Chest Radiographs: Comparison between Liquid Crystal Display and High-Resolution Cathode-Ray Tube Monitors
Radiology, February 1, 2005; 234(2): 611 - 616.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
Digitized conventional radiograph
Dentomaxillofac. Radiol., November 1, 2004; 33(6): 420 - 421.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. H. Fuchsjager, C. M. Schaefer-Prokop, E. Eisenhuber, P. Homolka, M. Weber, M. A. Funovics, and M. Prokop
Impact of Ambient Light and Window Settings on the Detectability of Catheters on Soft-Copy Display of Chest Radiographs at Bedside
Am. J. Roentgenol., November 1, 2003; 181(5): 1415 - 1421.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
R Haak, M. Wicht, G Nowak, and M Hellmich
Influence of displayed image size on radiographic detection of approximal caries
Dentomaxillofac. Radiol., July 1, 2003; 32(4): 242 - 246.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2002 by the British Institute of Radiology.