DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haak, R
Right arrow Articles by Hellmich, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haak, R
Right arrow Articles by Hellmich, M
Dentomaxillofacial Radiology (2003) 32, 242-246
© 2003 British Institute of Radiology
doi: 10.1259/dmfr/17654484


RESEARCH

Influence of displayed image size on radiographic detection of approximal caries

R Haak*,1, MJ Wicht1, G Nowak1 and M Hellmich2

1 Centre of Dental Medicine, Department of Operative Dentistry and Periodontology, University of Cologne, Köln, Germany; 2 Department of Medical Statistics, Informatics and Epidemiology, University of Cologne, Germany

*Correspondence to: Rainer Haak, University of Cologne, Centre of Dental Medicine, Department of Operative Dentistry and Periodontology, Kerpener Str. 32, D-50937 Köln, Germany; E-mail: rainer.haak{at}medizin.uni-koeln.de

Received 4 November 2002; revised 20 May 2003; accepted 5 June 2003

Objectives: To evaluate the validity of approximal caries detection on digital bitewing radiographs displayed at different image sizes on either a cathode ray tube (CRT) monitor or a thin film transistor (TFT) monitor.

Methods: Five observers assessed digital radiographs of a charge-coupled device (CCD)-based sensor system (Sidexis®) of 160 unrestored premolars and molars for approximal caries using a six category caries rating scale. Images were displayed at ratios of 1:1, 1:2 and 1:7 on a CRT monitor (Nokia 446 XS) and a TFT display (Panasonic LC 50S). Histological assessments of serial sections were used as the validation standard. Diagnostic accuracy was expressed as area under the receiver operating characteristic (ROC) curve (AUC) and was calculated at two levels of caries penetration: presence of caries (I) and presence of a lesion in the dentine (II). The influence of the factors "monitor type", "image size" and "validation threshold" were analysed with repeated measures analysis of variance.

Results: The ROC curve areas for approximal caries detection at both histological penetration levels were not influenced by the type of monitor display, whereas image size had a significant impact (P<0.01). AUCs for image size 1:7 (I, 0.62; II, 0.65) were smaller compared with ratios of 1:1 and 1:2 (P<0.01). No differences were observed between image size ratios 1:1 (I, 0.69; II, 0.74) and 1:2 (I, 0.68; II, 0.73).

Conclusions: In this study, the type of monitor did not influence approximal caries detection on digital radiographs. Image sizes with a display ratio of 1:1 and 1:2 resulted in better diagnostic validity than those with a ratio of 1:7.

Keywords: digital radiography, dental; image processing; data display; dental caries




This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
V Seneadza, A Koob, J Kaltschmitt, H J Staehle, J Duwenhoegger, and P Eickholz
Digital enhancement of radiographs for assessment of interproximal dental caries
Dentomaxillofac. Radiol., March 1, 2008; 37(3): 142 - 148.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
W. Berkhout, J. Verheij, K Syriopoulos, G Li, G. Sanderink, and P. van der Stelt
Detection of proximal caries with high-resolution and standard resolution digital radiographic systems
Dentomaxillofac. Radiol., May 1, 2007; 36(4): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
A Wenzel
A review of dentists' use of digital radiography and caries diagnosis with digital systems.
Dentomaxillofac. Radiol., September 1, 2006; 35(5): 307 - 314.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
S Prapayasatok, A Janhom, K Verochana, and S Pramojanee
Digital camera resolution and proximal caries detection.
Dentomaxillofac. Radiol., July 1, 2006; 35(4): 253 - 257.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
S Kositbowornchai, M Basiw, Y Promwang, H Moragorn, and N Sooksuntisakoonchai
Accuracy of diagnosing occlusal caries using enhanced digital images
Dentomaxillofac. Radiol., July 1, 2004; 33(4): 236 - 240.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2003 by the British Institute of Radiology.