Objective: The purpose of this paper is to present the system configuration and physical properties of a new dentomaxillofacial X-ray cone beam CT system (CB MercuRayTM) being developed.
Methods: The system consists of an image intensifier and a cone beam X-ray source. There are two different models of this system, each with a different size image intensifier, 9'' or 12''. Each system has three field of view (FOV) modes. The 12'' system has facial (F), panoramic (P) and implant (I) FOV modes. The 9'' system has P, I and dental (D) modes. Images produced by these systems consist of 512x512x512 isotropic voxels. Physical properties such as resolution, noise and distortion of the images were evaluated in this study. Modulation transfer function (MTF) was measured using Boone's method. Image noise was measured as the standard deviation of the CT value in water. Circularity of the axial images yielded by the two models was measured using an 8 mm diameter acrylic pipe phantom.
Results: The resolving power at a MTF of 0.1 in the D mode was over 2.0 lp mm1, suggesting that this system yields images of high resolution. The standard deviation of the CT value in water was approximately 80, which is thought to be greater than that of conventional CT. The circularity of images of the pipe phantom was 99% of the ideal value.
Conclusion: This study shows that our newly developed cone beam CT system produces high resolution three-dimensional volumetric images that will be useful for the examination of dentomaxillofacial disorders.
Keywords: tomography, X-ray computed; radiography, dental; tomography scanners, X-ray computed
This article has been cited by other articles:
![]() |
S. Stratemann, J. Huang, K Maki, A. Miller, and D. Hatcher Comparison of cone beam computed tomography imaging with physical measures Dentomaxillofac. Radiol., February 1, 2008; 37(2): 80 - 93. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Suomalainen, T Vehmas, M Kortesniemi, S Robinson, and J Peltola Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography Dentomaxillofac. Radiol., January 1, 2008; 37(1): 10 - 17. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Haiter-Neto, A Wenzel, and E Gotfredsen Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions Dentomaxillofac. Radiol., January 1, 2008; 37(1): 18 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Suomalainen, A Salo, S Robinson, and J. Peltola The 3DX multi image micro-CT device in clinical dental practice Dentomaxillofac. Radiol., February 1, 2007; 36(2): 80 - 85. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Pinsky, S Dyda, R. Pinsky, K. Misch, and D. Sarment Accuracy of three-dimensional measurements using cone-beam CT Dentomaxillofac. Radiol., November 1, 2006; 35(6): 410 - 416. [Abstract] [Full Text] [PDF] |
||||
![]() |
D Schulze, M Blessmann, P Pohlenz, K. Wagner, and M Heiland Diagnostic criteria for the detection of mandibular osteomyelitis using cone-beam computed tomography. Dentomaxillofac. Radiol., July 1, 2006; 35(4): 232 - 235. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |