| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
RESEARCH |
1 Department of Radiology, School of Dentistry, University of São Paulo, Brazil; 2 Department of Operative Dentistry, School of Dentistry, University of São Paulo, Brazil
*Correspondence to: Cesar Lascala, Departamento de Estomatologia, Faculdade de Odontologia, Universidade de São Paulo, Av. Prof. Lineu Prestes, 2227, São Paulo SP, 05508-900, Brazil; Email: cesaralascala{at}uol.com.br
Received 4 March 2004; revised 16 July 2004; accepted 19 July 2004
Objectives: The conical beam computed tomography (CBCT) technique presents an innovation of tomographic imaging systems and subsequent volumetric image reconstruction for dentistry. When compared with other methods of tomographic imaging CBCT is characterized by rapid volumetric image acquisition from a single low radiation dose scan of the patient. The NewTom (NewTom 9000; Quantitative Radiology, Verona, Italy) is an example of such a CBCT machine dedicated to dental and maxillofacial imaging, particularly for surgical and/or prosthetics implant planning in the field of dentistry. The aim of this study was to evaluate the accuracy of the linear measurements obtained in CBCT images using a NewTom.
Methods: Thirteen measurements were obtained in dry skulls (n=8) between internal and external anatomical sites using a caliper. These were considered as real measurements. Then the dry skulls were submitted to CBCT imaging examinations. Radiographic distance measurements of the same dry skull anatomical sites were made using the NewTom QR-DVT 9000 software of the 2 mm-CTs axial section images and sagittal or coronal reconstructions. The data were compared by paired Student's t-test.
Results: The results showed that the real measurements were always larger than those for the CBCT images, but these differences were only significant for measurements of the internal structures of the skull base.
Conclusions: The conclusion of this study is that, although the CBCT image underestimates the real distances between skull sites, differences are only significant for the skull base and therefore it is reliable for linear evaluation measurements of other structures more closely associated with dentomaxillofacial imaging.
Keywords: computed tomography; cone beam; X-ray computed; skull
This article has been cited by other articles:
![]() |
A Suomalainen, T Vehmas, M Kortesniemi, S Robinson, and J Peltola Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography Dentomaxillofac. Radiol., January 1, 2008; 37(1): 10 - 17. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Haiter-Neto, A Wenzel, and E Gotfredsen Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions Dentomaxillofac. Radiol., January 1, 2008; 37(1): 18 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Santos, M. Dutra, C Costa, C. Lascala, C. Lascala, and J. de Oliveira Aplasia of the mandibular condyle Dentomaxillofac. Radiol., October 1, 2007; 36(7): 420 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Kumar, J. Ludlow, A Mol, and L Cevidanes Comparison of conventional and cone beam CT synthesized cephalograms Dentomaxillofac. Radiol., July 1, 2007; 36(5): 263 - 269. [Abstract] [Full Text] [PDF] |
||||
![]() |
H Hintze, M Wiese, and A Wenzel Cone beam CT and conventional tomography for the detection of morphological temporomandibular joint changes Dentomaxillofac. Radiol., May 1, 2007; 36(4): 192 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Draenert, E Coppenrath, P Herzog, S Muller, and U. Mueller-Lisse Beam hardening artefacts occur in dental implant scans with the NewTom(R) cone beam CT but not with the dental 4-row multidetector CT Dentomaxillofac. Radiol., May 1, 2007; 36(4): 198 - 203. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Pinsky, S Dyda, R. Pinsky, K. Misch, and D. Sarment Accuracy of three-dimensional measurements using cone-beam CT Dentomaxillofac. Radiol., November 1, 2006; 35(6): 410 - 416. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |