DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lascala, C.
Right arrow Articles by Marques, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lascala, C.
Right arrow Articles by Marques, M.
Dentomaxillofacial Radiology (2004) 33, 291-294
© 2004 British Institute of Radiology
doi: 10.1259/dmfr/25500850


RESEARCH

Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)

CA Lascala*,1, J Panella1 and MM Marques2

1 Department of Radiology, School of Dentistry, University of São Paulo, Brazil; 2 Department of Operative Dentistry, School of Dentistry, University of São Paulo, Brazil

*Correspondence to: Cesar Lascala, Departamento de Estomatologia, Faculdade de Odontologia, Universidade de São Paulo, Av. Prof. Lineu Prestes, 2227, São Paulo SP, 05508-900, Brazil; Email: cesaralascala{at}uol.com.br

Received 4 March 2004; revised 16 July 2004; accepted 19 July 2004

Objectives: The conical beam computed tomography (CBCT) technique presents an innovation of tomographic imaging systems and subsequent volumetric image reconstruction for dentistry. When compared with other methods of tomographic imaging CBCT is characterized by rapid volumetric image acquisition from a single low radiation dose scan of the patient. The NewTom (NewTom 9000; Quantitative Radiology, Verona, Italy) is an example of such a CBCT machine dedicated to dental and maxillofacial imaging, particularly for surgical and/or prosthetics implant planning in the field of dentistry. The aim of this study was to evaluate the accuracy of the linear measurements obtained in CBCT images using a NewTom.

Methods: Thirteen measurements were obtained in dry skulls (n=8) between internal and external anatomical sites using a caliper. These were considered as real measurements. Then the dry skulls were submitted to CBCT imaging examinations. Radiographic distance measurements of the same dry skull anatomical sites were made using the NewTom QR-DVT 9000 software of the 2 mm-CTs axial section images and sagittal or coronal reconstructions. The data were compared by paired Student's t-test.

Results: The results showed that the real measurements were always larger than those for the CBCT images, but these differences were only significant for measurements of the internal structures of the skull base.

Conclusions: The conclusion of this study is that, although the CBCT image underestimates the real distances between skull sites, differences are only significant for the skull base and therefore it is reliable for linear evaluation measurements of other structures more closely associated with dentomaxillofacial imaging.

Keywords: computed tomography; cone beam; X-ray computed; skull




This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
A Suomalainen, T Vehmas, M Kortesniemi, S Robinson, and J Peltola
Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
Dentomaxillofac. Radiol., January 1, 2008; 37(1): 10 - 17.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F Haiter-Neto, A Wenzel, and E Gotfredsen
Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
Dentomaxillofac. Radiol., January 1, 2008; 37(1): 18 - 22.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
K. Santos, M. Dutra, C Costa, C. Lascala, C. Lascala, and J. de Oliveira
Aplasia of the mandibular condyle
Dentomaxillofac. Radiol., October 1, 2007; 36(7): 420 - 422.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
V Kumar, J. Ludlow, A Mol, and L Cevidanes
Comparison of conventional and cone beam CT synthesized cephalograms
Dentomaxillofac. Radiol., July 1, 2007; 36(5): 263 - 269.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
H Hintze, M Wiese, and A Wenzel
Cone beam CT and conventional tomography for the detection of morphological temporomandibular joint changes
Dentomaxillofac. Radiol., May 1, 2007; 36(4): 192 - 197.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
F. Draenert, E Coppenrath, P Herzog, S Muller, and U. Mueller-Lisse
Beam hardening artefacts occur in dental implant scans with the NewTom(R) cone beam CT but not with the dental 4-row multidetector CT
Dentomaxillofac. Radiol., May 1, 2007; 36(4): 198 - 203.
[Abstract] [Full Text] [PDF]


Home page
Dentomaxillofac RadiolHome page
H. Pinsky, S Dyda, R. Pinsky, K. Misch, and D. Sarment
Accuracy of three-dimensional measurements using cone-beam CT
Dentomaxillofac. Radiol., November 1, 2006; 35(6): 410 - 416.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING ALL BIR JOURNALS
Copyright © 2004 by the British Institute of Radiology.