DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haiter-Neto, F
Right arrow Articles by Bóscolo, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haiter-Neto, F
Right arrow Articles by Bóscolo, F.
Dentomaxillofacial Radiology (2005) 34, 133-139
© 2005 British Institute of Radiology
doi: 10.1259/dmfr/92119765


RESEARCH

Linear and logarithmic subtraction for detecting enamel subsurface demineralization

F Haiter-Neto*,1, RI Ferreira1, CPM Tabchoury2 and FN Bóscolo1

1 Department of Oral Diagnosis, Division of Oral and Maxillofacial Radiology, Piracicaba Dental School, University of Campinas, São Paulo, Brazil; 2 Department of Physiological Sciences, Division of Biochemistry, Piracicaba Dental School, University of Campinas, São Paulo, Brazil

*Correspondence to: F Haiter-Neto, Department of Oral Diagnosis, Division of Oral and Maxillofacial Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Areião, Piracicaba, São Paulo, 13414-903 Brazil; E-mail: haiter{at}fop.unicamp.br

Received 25 August 2004; revised 17 December 2004; accepted 29 December 2004

Objective: To compare the diagnostic performance of linear and logarithmically contrast-enhanced subtraction images, acquired with digital and digitized radiographs, in detecting approximal enamel subsurface demineralization.

Methods: Fifty caries-free human third molars were immersed in a demineralizing solution for 60, 75, 90, and 120 days, in order to induce artificial enamel subsurface demineralization. The teeth were coated with nail varnish, leaving only a circular window of approximately 7 mm2 in one of the approximal surfaces, allowing contact with the solution. Standardized radiographs of the teeth were taken prior to and after the demineralization period with three digital systems, CygnusRay MPS®, DenOptix® and DIGORA®, and InSight® film. Conventional, digital and digitized radiographs were assessed by three experienced radiologists. Linear and logarithmically contrast-enhanced subtraction images were acquired and then examined by a fourth independent radiologist. For the validation of the radiographic diagnosis, the enamel test areas were submitted to Knoop microhardness profiling. Radiographic interpretation data was evaluated using ROC analysis. The areas under the ROC curves (Az) were compared by the chi-squared test. The level of significance was set at P=0.05.

Results: No significant differences were found between linear and logarithmically contrast- enhanced subtraction images, acquired with the four studied modalities: CygnusRay MPSlinear® (Az=0.95), CygnusRay MPSlog® (Az=0.98), DenOptixlinear® (Az=0.97), DenOptixlog® (Az=0.99), DIGORAlinear® (Az=0.98), DIGORAlog® (Az=0.98), digitized radiographylinear (Az=0.99), digitized radiographylog (Az=0.99).

Conclusion: Linear and logarithmically contrast-enhanced subtraction images, acquired with digital and digitized radiographs, were diagnostically comparable for assessing enamel subsurface demineralization.

Keywords: dental caries; diagnosis; diagnostic imaging; subtraction techniques




This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
P Guneri, S Gogus, Z Tugsel, and H Boyacioglu
Efficacy of a new software in eliminating the angulation errors in digital subtraction radiography
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 484 - 489.
[Abstract] [Full Text] [PDF]