DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Akdeniz, B.
Right arrow Articles by Gröndahl, H-G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Akdeniz, B.
Right arrow Articles by Gröndahl, H-G
Dentomaxillofacial Radiology (2006) 35, 74-77
© 2006 British Institute of Radiology
doi: 10.1259/dmfr/51534985


RESEARCH

Degradation of storage phosphor images due to scanning delay

BG Akdeniz*,1 and H-G Gröndahl2

1 Department of Oral Diagnosis and Radiology, School of Dentistry, Ege University, Izmir, Turkey; 2 Oral and Maxillofacial Radiology, The Sahlgrenska Academy, Göteborg University, Göteborg, Sweden

*Correspondence to: BG Akdeniz, Ege Universitesi, Dishekimligi Fakultesi, Oral Diagnoz & Rad AD, Bornova, 35100, Izmir, Turkey; Email: bgunb{at}yahoo.com

Received 21 February 2005; accepted 26 June 2005

Objective: To evaluate the degradation of storage phosphor images relative to scanning delay.

Methods: A series of exposures of an aluminium step-wedge with five 2 mm incremental steps were made using blue Digora® storage phosphor plates (SPPs). After the first exposure the plates were immediately scanned. After the second the plates were scanned after a half hour delay, after the third after a 1 h delay and so on until a final delay of 8 h. Mean grey values (MGVs) of each step of the wedge and its background were compared using repeated measures analysis of variance (ANOVA). Difference between group means was assessed using Bonferroni/Dunn multiple comparison test (P<0.05).

Results: MGVs increased with the increase in scan delay. Repeated measures ANOVA revealed that MGVs of the background and each step of the wedge were significantly different from each other for all scan delays (P<0.0001). Bonferroni/Dunn test showed that MGVs from plates scanned half an hour after exposure were not significantly different from those scanned immediately (P>0.05). Longer delays gave rise to significant differences in MGVs (P<0.05).

Conclusion: Digora® SPPs show statistically significant degradation of grey level values and contrast in plates scanned half an hour or longer after exposure.