DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prapayasatok, S
Right arrow Articles by Pramojanee, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prapayasatok, S
Right arrow Articles by Pramojanee, S
Dentomaxillofacial Radiology (2006) 35, 253-257
© 2006 British Institute of Radiology
doi: 10.1259/dmfr/32165678


RESEARCH

Digital camera resolution and proximal caries detection

S Prapayasatok*, A Janhom, K Verochana and S Pramojanee

Department of Oral Radiology, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand

*Correspondence to: Sangsom Prapayasatok, Department of Oral Radiology, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand; Email: sangsom{at}chiangmai.ac.th

Received 19 April 2005; revised 28 September 2005; accepted 13 October 2005

Objectives: To evaluate the diagnostic accuracy of proximal caries detection from digitized film images captured by a digital camera at different resolution settings.

Methods: Twenty-five periapical radiographs of 50 premolar and 25 molar teeth were photographed using a digital camera, Sony Cyber-shot, DSC-S75 at three different resolution settings: 640x480, 1280x960 and 1600x1200. Seventy-five digital images were transferred to a computer, saved and opened using ACDSee software. In addition, a PowerPoint slide was made from each digital image. Five observers scored three groups of images (the films, the displayed 1:1 digital images on the ACDSee software, and the PowerPoint slides) for the existence of proximal caries using a 5-point confidence scale, and the depth of caries on a 4-point scale. Ground sections of the teeth were used as the gold standard. Az values under the receiver operating characteristic (ROC) curve of each group of images and at different resolutions were compared using the Friedman and Wilcoxon signed rank tests. Mean different values between the lesions' depth interpreted by the observers and that of the gold standard were analysed.

Results: Films showed the highest Az values. Only the 1280x960 images on the ACDSee software showed no significant difference of the Az value from the films (P=0.28). The digital images from three resolution settings on the PowerPoint slides showed no significant differences, either among each other or between them and the films. For caries depth, the 1280x960 images showed lower values of mean difference in enamel lesions compared with the other two resolution groups.

Conclusions: This study showed that in order to digitize conventional films, it was not necessary to use the highest camera resolution setting to achieve high diagnostic accuracy for proximal caries detection. The 1280x960 resolution setting of the digital camera demonstrated comparable diagnostic accuracy with film and was adequate for digitizing radiographs for caries detection.

Keywords: digital radiography; digital camera; dental caries; image resolution




This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
G Li, W E R Berkhout, G C H Sanderink, M Martins, and P F van der Stelt
Detection of in vitro proximal caries in storage phosphor plate radiographs scanned with different resolutions
Dentomaxillofac. Radiol., September 1, 2008; 37(6): 325 - 329.
[Abstract] [Full Text] [PDF]