DMFR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olszewski, R
Right arrow Articles by Zech, F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olszewski, R
Right arrow Articles by Zech, F
Dentomaxillofacial Radiology (2008) 37, 261-267
© 2008 British Institute of Radiology
doi: 10.1259/dmfr/33343444


RESEARCH

Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph

R Olszewski*,1, H Reychler1, G Cosnard2, J M Denis3, S Vynckier3 and F Zech4

1Department of Oral and Maxillofacial Surgery, Saint Luc University Clinics, Université Catholique de Louvain, Brussels, Belgium; 2Department of Medical Imaging, Saint Luc University Clinics, Université Catholique de Louvain, Brussels, Belgium; 3Department of Radiotherapy and Oncology, Saint Luc University Clinics, Université Catholique de Louvain, Brussels, Belgium;, 4Department of Internal Medicine, Saint Luc University Clinics, Université Catholique de Louvain, Brussels, Belgium

*Correspondence to: Raphael Olszewski, DDS, MD, Department of Oral and Maxillofacial Surgery (Head: Prof. H Reychler), Av. Hippocrate 10, Saint Luc University Clinics, Université Catholique de Louvain, 1200 Brussels, Belgium. E-mail: raphael.olszewski{at}stom.ucl.ac.be

Received 13 June 2007; revised 26 September 2007; accepted 26 September 2007

Objectives: The aim of this paper is to compare the accuracy of cephalometric landmark identification using three-dimensional CT (3D-CT) surface rendering with "high-dose" (200 mAs) and "low-dose" (35 mAs) CT protocols. The absorbed dose levels for radiosensitive organs in the maxillofacial region during the exposure for both 3D-CT protocols were also measured.

Methods: The study population consisted of 15 human dry skulls examined with spiral 3D-CT. 12 cephalometric anatomical landmarks at 7 sites were identified on the 3D-CT surface renderings by 2 observers independently, twice each, using high-dose and low-dose protocols. In total, 1440 imaging measurements were made. Thermoluminescent dosemeters (TLDs) were placed at ten sites around the thyroid and submandibular glands and the eyes in an Alderson phantom for measuring the absorbed dose levels.

Results: The intraobserver mean distances between 3D landmarks were smaller for all sites with the high-dose protocol (P = 0.37). There was a significant difference among the observers (P = 0.000004). Interobserver mean distances between 3D landmarks were smaller for four of the seven sites with the low-dose protocol. However, the global interobserver mean distances between 3D landmarks for all sites were smaller with the high-dose protocol (P = 0.028). The low-dose protocol reduced the radiation dose to the thyroid by 6.12, to the submandibular salivary glands by 5.91 and to the eye by 5.44, resulting in a global reduction factor of 5.71.

Conclusions: The accuracy in the landmark's identification was maintained when the milliampere-second values were reduced from 200 mAs to 35 mAs. We recommend use of the low-dose protocol for clinical 3D-CT cephalometric applications.

Keywords: three-dimensional; computed tomography; cephalometry; dose reduction




This article has been cited by other articles:


Home page
J. Orthod.Home page
Relevant research from non-orthodontic journals
J. Orthod., December 1, 2008; 35(4): 283 - 286.
[Abstract] [Full Text] [PDF]